Super Therm® Application Instructions

The application of Super Therm is easy however you must follow the instructions.

Great application benefits:

  • Save time and reduce costs
  • No building materials or trades needed
  • A single coat application
  • No long-term maintenance required
  • Safe application
  • Quick heat protection solution
  • Instant results
  • Water soluble
  • Applied with brush, roller or airless sprayer* (*specific instruction)
  • 10 in 1 heat protection protection
Apply Super Therm® with 50% overlap

Although Super Therm® can be applied by non-professionals, NEOtech Coatings recommends using a NEOtech certified applicator.

Official Super Therm® Manufacturer Application Instructions – pdf

Super Therm® is considered a solar heat block coating. Therefore the application instructions must be followed to receive maximum benefits and desired outcome.

  • Super Therm® should not be diluted or thin
  • Super Therm®must be stirred for a minimum of 5 minutes to circulate all the ceramics effectively
  • The surface must be thoroughly clean and dry before application.

Simplified Application Instructions

Full and official manufacturer Super Therm® Application Instructions – pdf

Super Therm® is an energy efficient, highly advanced ceramic coating system (not a paint) that contains 4 unique ceramics that block up to 95% of solar heat entering a structure if applied as per the instructions below. The combination of proprietary ceramics, resins and a urethane bond to counteract the 4 methods of heat transfer: radiation; conduction; convection; and infrared.

NOTE: It is important for the desired outcome of Super Therm® that the application instructions below are followed correctly.

Super Therm® should not be diluted or thinned and stirred thoroughly for a minimum of 5 minutes

Surface Preparations

  • The surface must be clean from dust, oil, tar, rust, grease, salts, films or any contaminants.
  • Surface must be completely dry before applying.
  • Minimum surface temperature 5°C
  • Maximum surface temperature 65°C
  • Recommend drop sheets and caution as Super Therm® is difficult to clean up if spilt due to its bonding strength.

Stir Super Therm® thoroughly for a minimum of 5 minutes

Mixing

Due to it’s thick compounds Super Therm® is best mechanically mixed or mixed by hand (boxing) thoroughly for a minimum of 5 minutes then apply.

Application

Super Therm® can be applied by brush, roller or sprayed. The preferred method of application is by air or airless sprayer. Remove filters from the sprayer and apply on a day with no wind. Full detailed instructions to apply Super Therm® (pdf)

Spread & Coverage Rates

Super Therm® should be applied at no less than 17 mil wet = (425um Microns) and dries down to 10 mil = (250um Microns) after each application. The total Dry Film Thickness (DFT) is a quarter of a mm (business card thickness) at 250um Microns. Recommended coverage is 2.5m2 per litre.

Note: Roofs with corrugations

  • 2″ corrugation = roof size x 135%
  • 2.5″ corrugation = roof size x 145%
  • 3″ corrugation = roof size x 160%

Drying and Cure Times

  • First coat: 30-60 minutes to tack free at 21°c
  • Overcoat: 2 hours later at 21°c at 40% relative humidity
  • Full Cure: 21 days

Note: If Super Therm® is wet or rained on during the curing process it may bubble. Do not puncture these bubbles as the coating will settle down and retract to its natural state.

Clean Up

After completion tools should be cleaned with water; cleaned brushes and rollers can be reused.

Storage

Store between 5°c and 37°c and thoroughly close the container to air tight as Super Therm® will dry out.

Additional Strength

Super Therm® works best with Enamo Grip to seal, protect and finish and with Super Base to seal and prime the surface.


Super Therm® two reflective ceramics reflect sunlight and radiant heat while the third ceramic compound works to stop heat and/or cold conduction through the coating film the fourth ceramic blocks almost all infrared. The combination of acrylics provide elasticity and toughness while the urethane binds the acrylics and compounds, also providing a moisture barrier. The fourth resin additive is what makes the complete resin blend to combine into a single component and extends the life of the coating.

VOC-Compliant: Only 67 grams/litre. Limit is 420 grams. Water-based
USDA-Approved: For use in and around food preparation facilities
Mildew and mould: Can withstand moisture
Fire tested: “0” flame and smoke results. No off gassing (NASA)
Spread Rate: 2.4m2 per litre on roofing and walls.
New galvanized metal/slick metal surfaces, stainless steel and aluminium — apply Rust Grip at 3.37m2/litre as a primer first, then Super Therm® at 2.4m2 per litre (if rusted areas, Rust Grip at 2.53m2/litre as a primer)
Weathered metal surfaces: (5-10 years old), no primer needed Apply Super Therm® at 2.4m2 per litre (if no rust is present).
Concrete surfaces: If painted before, just make sure all loose or flaking paint is off first, then apply Super Therm® directly. If not painted before, seal concrete first using Super Base (HS) at 2.4m2 per litre, then apply Super Therm® .
Tar/Asphalt or Rubber Surfaces: Seal first with Super Base (HS) at 0.07m2/litre, then apply Super Therm® . Tar and asphalt will bleed oil residues into the coating, turning it brown and interfering with the ability of Super Therm® if not sealed first. Super Base (HS) is water-based and, therefore, will not soften or harm the tar/asphalt but will completely fill and seal all holes, cracks and broken seams.
Flat Roof Systems: Remove all loose gravel and power wash. Watch for roofs with consistent leaking; if present, push for roofing system #1 or #2.

System #1-Apply Super Base (HS) at 0.07m2/litre As you apply Super Base (HS), lay in the polyester membrane (36″ width x 360′ length) as you go. Let dry and re-apply Super Base (HS) over the membrane at 100 sq.ft./gallon. Let dry, then apply Super Therm® at 2.4m2/litre for the coating; and last apply SP Clear Protector at 6.1m2/litre as a top coat. Total mil thickness will be: Super Base (HS) -21 mils, mesh-6 mils, SUPER BASE (HS 7 mils, Super Therm® -7 mils, SP Clear Protector-2 mils 43 mills.

System #2–(solid roof, absolutely no leaks)-Apply Super Base (HS) at 0.7m2/litre Apply Super Therm® at 2.4m2/litre. 

Walls (interior/exterior): Apply Super Therm® at 2.4m2 per litre
Tinting: Can tint to any earth-tone colours. Not medium to dark tones. Never tint to grey-the black tint will cover the ceramic particles first and block their effectiveness. Best approach is to apply Super Therm® in 2 coats, let dry, then paint a coloured paint over the Super Therm® as your finishing coat
Acid/Salt-resistance: Will withstand mild acids and salt spray.
High humidity: After Super Therm® dries completely, no effect on coating.
UV/Weathering: Very UV-stable, will withstand basic weathering for 20 years minimum
Application: Always pressure clean substrate using a minimum of 3000 psi power washer to clean dirt, oils, etc. Use washing powders in washing systems and rinse well.

KW Reduction from Super Therm® = Actual Dollars

Looking to join one of the world’s leading coatings companies. Contact us if you’re a quality applicator looking for new products and markets!